Musculoskeletal system and artificial replacements
Biotribology of joint replacements
Project description:
Project is aimed at the realistic simulation of wear tribology of human joints. Is evaluated wear of articular components of different material combinations of the contact surfaces. Kinematics and dynamics are set according to relevant ISO standards (ISO 14243 for Total Knee Replacements). In addition, experiments are conducted under conditions that represent the real activities of daily living.
Ing. Jakub Kronek Ph.D.Resesrchers:
Medin Orthopaedic, corp
ProSpon spol. ltd
HVM Plasma, ltd
Institut of thermomechanics Adademy of Sciences of the Czech republic
Institute of Macromolecular Chemistry of Academy of Sciences of the Czech Republic
Faculty of Mechanical Engineering, TU Košice (Slovakia)
Cooperation:
Literature:
- Franta L., Novotný P., Suchánek J.: Influence of dynamic loading on the Wear of Knee Prosthesis. In Workshop Action - COST 533 - Biotribology. EIBAR: FUNDACIÓN TECHNIKER, 2008, vol. 1, p. 97-108.
- Franta L., Novotný P., Suchánek J.: Simulation of knee joint dynamics and kinematics under realistic conditions – part II.. In Human Biomechanics 2008 [CD-ROM]. Praha: Czech Society of Biomechanics, 2008, p. 102-103.
- Vojs M., Zdravecká E., Marton M., Bohač P., Franta L., et al.: Properties of amorphous carbon layers for bio-tribological applications. Microelectronics Journal. 2008, Vol. 2008
- Zdravecká E., Franta L., Pražák J., Boháč P., Vojs M.: Oteruvzdorne povlaky komponentov umelých klbov. In Škola vákuovej techniky: Vzájomná spolupráca pracovísk = kvalitný výskum. Bratislava: Slovenská vákuová spoločnosť, 2008, s. 70-74.
- Zdravecká E., Franta L., Pražák J.: Sliding friction measurement in lubricated contact between DLC and UHMWPE. MECHANIKA W MEDYCYNIE. 2008, vol. 2008, no. 9, p. 297-300.
- Zdravecká, E. - Tiainen, V.M. - Konttinen, Y.T. - Franta, L. - Vojs, M. - et al.: Relationships between the fretting wear behavior and mechanical properties of thin carbon films. In 13th Joint Vaccuum Conference, Book of Abstracts. Brno: Tribun EU, s.r.o., 2010, vol. 1, p. 108-110. ISBN 978-80-7399-969-8.
- Franta, L. - Kronek, J. - Suchánek, J.: TKA wear testing input after kinematic and dynamic meta-analysis: technique and proof of concept. Wear. 2011, vol. 2011(271), no. 9-10, p. 2687-2692. ISSN 0043-1648.
- Franta, L. - Fojt, Jaroslav - Joska, Luděk - Kronek, J. - Cvrček, Ladislav - et al.: Hinge-type knee prosthesis wear tests with a mechanical load and corrosion properties monitoring. Tribology International. 2012, vol. 2012, no. L, p. 1-10. ISSN 0301-679X.
- Franta, L. - Heralt, P. - Suchánek, J.: Heating of total knee joint replacements during normal walking. In Human Biomechanics 2010. Liberec: Technical University of Liberec, 2010, p. 67-71. ISBN 978-80-7372-648-5.
- Zdravecká, E. - Franta, L. - Ondáč, M.: The Carbon Layers for Bio-tribological Aplitions. In Zeszyty naukowe polytechniki Rzeszowskiej. Mechanika. Rzeszów: Oficyna wydawnicza Politechniki Rzeszowskiej, 2010, vol. 277, p. 151-154. ISSN 0209-2689.
- Heralt, P. - Franta, L. - Suchánek, J.: Heating of knee joint replacement on simulator during "ISO Gait" and normal physiological walking. In ECOTRIB 2011. Wien: The Austrian Tribology Society, 2011, vol. 1, p. 491-496. ISBN 978-3-901657-38-2.
- Suchánek, J. - Franta, L. - Kronek, J.: Knee Wear - Experimental Conditions for dynamic loading Tests. In IN-TECH 2010. Jaroměř: Tisk AS, s.r.o., 2010, vol. 1, p. 607-611. ISBN 978-80-904502-2-6.