Musculoskeletal system and artificial replacements
Experimental equipment
Research on tissues and body structures and biomaterials
Biotribology of joint replacements
Project description:
Project is aimed at the realistic simulation of wear tribology of human joints. Is evaluated wear of articular components of different material combinations of the contact surfaces. Kinematics and dynamics are set according to relevant ISO standards (ISO 14243 for Total Knee Replacements). In addition, experiments are conducted under conditions that represent the real activities of daily living.
Jakub Kronek MSc. ; Msc. Lukáš Franta,Resesrchers:
Medin Orthopaedic, corp., ProSpon spol. ltd., HVM Plasma, ltd., Institut of thermomechanics Adademy of Sciences of the Czech republic, Institute of Macromolecular Chemistry of Academy of Sciences of the Czech Republic, Faculty of Mechanical Engineering, TU Košice (Slovak)
Cooperation:
Literature:
- Franta L., Novotný P., Suchánek J.: Influence of dynamic loading on the Wear of Knee Prosthesis. In Workshop Action - COST 533 - Biotribology. EIBAR: FUNDACIÓN TECHNIKER, 2008, vol. 1, p. 97-108.
- Franta L., Novotný P., Suchánek J.: Simulation of knee joint dynamics and kinematics under realistic conditions – part II.. In Human Biomechanics 2008 [CD-ROM]. Praha: Czech Society of Biomechanics, 2008, p. 102-103.
- Vojs M., Zdravecká E., Marton M., Bohač P., Franta L., et al.: Properties of amorphous carbon layers for bio-tribological applications. Microelectronics Journal. 2008, Vol. 2008
- Zdravecká E., Franta L., Pražák J., Boháč P., Vojs M.: Oteruvzdorne povlaky komponentov umelých klbov. In Škola vákuovej techniky: Vzájomná spolupráca pracovísk = kvalitný výskum. Bratislava: Slovenská vákuová spoločnosť, 2008, s. 70-74.
- Zdravecká E., Vojs M., Tkáčová J., Franta L.: Comparative testing of amorphous carbon layers for biotribological aplications. In Book of Abstracts. Lisboa: New University of Lisabon, 2008, p. 95
- Zdravecká E., Franta L., Pražák J.: Sliding friction measurement in lubricated contact between DLC and UHMWPE. MECHANIKA W MEDYCYNIE. 2008, vol. 2008, no. 9, p. 297-300.